=Conductor: Stranded Tinned Copper
=Insulation: Semi-rigid PVC(SRPVC)
=Shield: Aluminum/Mylar foil with stranded,tinned copper drain wire plus overall braid of tinned copper
=Jacket: PVC
=Rated Temperature: 80℃
=Voltage Rating: 300 Volt
=Passes UL VW-ISC vertical flame test
UL Style&CSA Type
Conductor
No.of Pair
Insulation Thickness
Braid Shield
Jacket Thickness
Overall Diameter
Nominal Capa.
Standard Put-Up
AWG
No./mm
A
B
Ft/Coil
M/Coil
mm
pF/ft
UL2464CSA I/II A(AWM)
24
7/0.200
2
0.25
16/8/0.120
0.80
6.30±0.20
30
50
1000
305
3
0.85
6.90±0.20
500
152
4
24/8/0.120
7.20±0.20
5
7.40±0.20
6
7.70±0.20
7
1.02
8.30±0.20
8
8.50±0.20
10
9.50±0.25
12.5
24/10/0.120
10.10±0.30
15
11.20±0.30
18
12.10±0.35
25
13.00±0.35
A:Capactiance between conductors
B:Capactiance between one conductors and other conductors connected to shield
Note:Capacitance is measured at 1KHz